Description:
ATR3110 portable Raman spectrometer fit to laboratory work. With high reliable measuring accuracy, excellent low stray light condition, it enables a wide range of application, especially in sectors of biochemical analyzer, public safety, food safety, pharmaceutical engineering etc. The multi-function software facilitated the spectral analysis process in application. The remote experiment through internet access makes the test item much easier.ATR3110 built-in excellent algorithm, which can identify substances at ease, meanwhile it can add one's own spectral data.A user-friendly interface for both technical & non-technical users to make their job easier. High-quality hardware configuration and robust multivariate algorithms guarantee accurate, uniform and reliable results detected.
Features:
High Sensitivity & Resolution
TE-cooled, down to -10℃,
Ultra-low noise circuit;
Powerful embedded software;
Fluorescence background elimination;
Peak finding and display;
USB 2.0;
Application:
Bioscience
Material science
Pharmaceutical engineering
Forensic analysis
Agriculture and food safety
Gemstones identification
Environmental science
Graphene
Nano materials
ATR3110 System | |||
Interface | USB 2.0 and WIFI | ||
Operating system | Windows 10 | ||
Integration time | 4ms - 120s | ||
Power voltage | DC 19V(+/-5%) | ||
Operating Temp | -10~40 ℃ | ||
Operating humidity | < 95% | ||
Dimension(L*W*H) | 26x33x16.5cm | ||
Weight | 5.5 Kg | ||
Reliability | |||
Spectral stability | σ/μ < 0.5% (COT 8 hours) | ||
Temp stability | Spectral shift ≤ 1 cm-1 (10-40 ℃) | ||
Variation of intensity(in 5 ~ 40 ℃) | <±5% | ||
Optical parameters | |||
Spectral range (cm-1) | 200-2700 | 200-3500 | 200-4300 |
resolution (cm-1) | 5-6 | 7-8 | 10-15 |
SNR | >3000:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW) | ||
Entrance slit | 50 μm | ||
Optical system | f/4 C-T crossed optical path | ||
focusing | 98 mm for incidence and output | ||
Detector | |||
Item | Ultra-high sensitivity, quick cooling CCD | ||
Detector cooled down to | -10 ℃ | ||
Detecting range | 200-1100 nm | ||
Effective pixels | 2048*64 | ||
Dynamic range | 50000:1 | ||
Pixel size | 14μm×14μm | ||
Full well capacity | 300 Ke- | ||
Sensitivity | QE>40%, 6.5 μV/e- | ||
Exciting Laser | |||
Central wavelength | 785nm (+/-1nm) | ||
FWHM | 0.08 nm | ||
Power output | ≥500 mW | ||
Power stability | σ/μ <±0.2% | ||
Raman probe | |||
Operating distance | 6 mm | ||
Rayleigh scattering resistance | OD>8 | ||
Numerical Aperture | 0.3 | ||
Aperture | 7mm |
상품의 사용후기를 적어주세요.
게시물이 없습니다
상품에 대해 궁금한 점을 해결해 드립니다.
게시물이 없습니다